Our website uses necessary cookies to enable basic functions and optional cookies to help us to enhance your user experience. Learn more about our cookie policy by clicking "Learn More".
Accept All Only Necessary Cookies
ZELIO Wi-Fi TCP/Modbus icon

1.3 by Giuseppe CURCIO


Feb 12, 2016

About ZELIO Wi-Fi TCP/Modbus

Dialogue in Wi-Fi with smart relays Zelio + Ethernet module connected to the access point

ITA:

Questa applicazione consente di interfacciarsi con uno smart-relè Zelio provvisto del modulo Ethernet connesso a un Access-Point.

Una volta digitato l'indirizzo IP del modulo Ethernet dello Zelio e attivata la connessione è possibile

leggere i registri interni dello smart-relè, in particolare sia quelli "scrivibili" (denominati j1XT1, j2XT1, j3XT1 e j4XT1) 4x00016, 4x00017, 4x00018 e 4x00019 sia quelli solo "leggibili" (denominati o1XT1, o2XT1, o3XT1 e o4XT1) 4x00020, 4x00021, 4x00022 e 4x00023 (scritti dall'interno del programma dello Zelio in FBD)

I valori letti sono rappresentati in modalità:

UINT=> 16bits non segnati

INT=> 16bits segnati

HEXA=> esadecimale

BIN=> 16bits rappresentati in nibble (in gruppi di 4)

E' anche possibile, selezionando il registro relativo scrivere un valore settabile in modalità UINT oppure con 16 selettori uno per ciascuno dei bits componenti la variabile medesima in modalità BINARIA.

Sono stati implementati alcuni controlli sui campi indirizzo IP, selezione registro da scrivere e valore impostato in tale registro.

Lo stato della connessione è sempre disponibile in alto a destra dello schermo.

La visione del filmato facilita la comprensione della modalità operativa nell'uso dell'applicazione

ENG:

This application allows you to interface with a smart-relay Zelio provided Ethernet module connected to an access point.

After entering the IP address of the Ethernet module and the Zelio activated the connection is possible to read the internal registers of the smart-relay, in particular and those "writable" (called j1XT1, j2XT1, j3XT1 and j4XT1) 4x00016, 4x00017, 4x00018 and 4x00019 and those only "readable" (called O1XT1, o2XT1, o3XT1 and O4XT1) 4x00020 , 4x00021, 4x00022 and 4x00023 (written from within the program of Zelio in FBD).

The values are represented in the mode:

UINT => 16bits unsigned

INT => 16bits signed

HEXA => hexadecimal

BIN => 16bits represented in nibble (in groups of 4)

It is possible, by selecting the record to write a value (settable mode UINT) or with 16 switches one for each of the bits making up the same variable in BINARY mode.

Have been implemented some controls on the fields IP address, selection register to write and value set in this register.

The connection status is always available at the top right of the screen.

The vision of the video facilitates the understanding of the mode of operation in the use of the application

What's New in the Latest Version 1.3

Last updated on Feb 12, 2016

ITA:
In questa ultima versione è stata introdotta la "retentività della comunicazione" fino a quando l’applicazione non viene chiusa.
In questo modo il dispositivo non entra più in stand-by finchè non si preme il pulsante di uscita.

ENG:
This latest version has been introduced the “keeping communication” until the application is closed.
In this way, the device does not go into standby mode (sleep state) until You press the exit button.

Translation Loading...

Additional APP Information

Latest Version

Request ZELIO Wi-Fi TCP/Modbus Update 1.3

Uploaded by

لخضر محمد

Requires Android

Android 1.6+

Show More

ZELIO Wi-Fi TCP/Modbus Screenshots

Comment Loading...
Subscribe to APKPure
Be the first to get access to the early release, news, and guides of the best Android games and apps.
No thanks
Sign Up
Subscribed Successfully!
You're now subscribed to APKPure.
Subscribe to APKPure
Be the first to get access to the early release, news, and guides of the best Android games and apps.
No thanks
Sign Up
Success!
You're now subscribed to our newsletter.